A 21 ft length of 2 inch Schedule 40 steel pipe weighs about 77 lb: 3.66 lb per foot. Full of water it weighs 107 lb, because it holds 3.7 gallons. The calculator above does this for any NPS from ½ to 12 in Schedule 40 or 80, or for any outside diameter and wall, in steel, stainless, aluminum, copper, brass, cast iron, PVC, HDPE or polypropylene.
How the calculator works
Choose the pipe size and schedule, or "Other outside diameter" for tubing and odd sizes, then the material, the length of one piece and how many. The result is the total weight, weight per foot, one piece, the cross-section area of the wall, the inside diameter, how much the pipe holds and what it weighs full of water.
The formula
The wall is a ring: area = π ÷ 4 × (OD² − ID²), with ID = OD − 2 × wall. For steel at 490 lb/ft³ this simplifies to the formula in the standard: lb per foot = 10.69 × (OD − wall) × wall, in inches. For NPS 4 Schedule 40: 10.69 × (4.500 − 0.237) × 0.237 = 10.8 lb per foot, the plain-end weight in ASME B36.10.
NPS is a name, not a size
Nominal pipe size does not measure anything. Up to NPS 12 the outside diameter is larger than the number, and every schedule of one size has the same outside diameter: the extra wall of Schedule 80 goes inside, so the bore gets smaller. That is why fittings fit any schedule of the same size.
| NPS | Outside diameter, in | Sch 40 wall, in | Sch 40, lb/ft | Sch 80, lb/ft | Water, gal/ft (Sch 40) |
|---|---|---|---|---|---|
| ½ | 0.840 | 0.109 | 0.85 | 1.09 | 0.016 |
| ¾ | 1.050 | 0.113 | 1.13 | 1.48 | 0.028 |
| 1 | 1.315 | 0.133 | 1.68 | 2.17 | 0.045 |
| 1½ | 1.900 | 0.145 | 2.72 | 3.64 | 0.106 |
| 2 | 2.375 | 0.154 | 3.66 | 5.03 | 0.174 |
| 3 | 3.500 | 0.216 | 7.58 | 10.26 | 0.384 |
| 4 | 4.500 | 0.237 | 10.80 | 15.00 | 0.661 |
| 6 | 6.625 | 0.280 | 18.99 | 28.60 | 1.501 |
| 8 | 8.625 | 0.322 | 28.58 | 43.43 | 2.599 |
| 12 | 12.750 | 0.406 | 53.58 | 88.72 | 5.815 |
Dimensions from ASME B36.10; weights computed at 490 lb/ft³ and within 0.2 % of the tabulated plain-end weights. Threaded and coupled pipe weighs a little more.
Capacity and weight full of water
The bore holds π ÷ 4 × ID² per unit length: in gallons per foot, 0.0408 × ID². Water weighs 8.34 lb per gallon. Pipe supports and hangers carry the pipe and its contents, so the weight full of water is the one to use for spacing hangers or sizing a rack.
Plastic and other metals
PVC Schedule 40 and 80 use the same outside diameters as steel (iron pipe size, ASTM D1785), so the size list works for them too; PVC weighs about 18 % of steel, HDPE and polypropylene about 12 %. Stainless pipe follows ASME B36.19 with its own thin schedules (5S, 10S) but the same outside diameters; enter the wall for those. Copper tube for plumbing is sized differently (types K, L and M); use "Other outside diameter".
Common mistakes
- Taking NPS 2 as 2 inches across. It is 2.375 in outside and 2.067 in inside in Schedule 40.
- Assuming Schedule 80 is bigger outside. Only the wall changes.
- Sizing supports for empty pipe. A 6 in water line weighs 19 lb per foot empty and 31.5 lb full.
For square and rectangular tubing, see the Tube Weight Calculator; for bar, plate and angle, the Steel Weight Calculator.